Fluke 1555

Fluke 1555
Harga Rp 0
Persediaan Ada
Kode Insulation Resistance Tester

Jumlah Add to Cart

The 1555 and redesigned Fluke 1550C insulation resistance testers, offer digital insulation testing up to 10kV, making them ideal for testing a wide range of high voltage equipment including switch gear, motors, generators and cables. Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1555 and 1550C are perfect tools for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.

 

Insulation resistance measurement

Test voltage (dc)

Range (dc)

Accuracy (± reading)

250 V < 200 kΩ
200 kΩ to 5 GΩ
5 GΩ to 50 GΩ
> 50 GΩ
unspecified 
5 % 
20 % 
unspecified
500 V   200 kΩ
200 kΩ to 10 GΩ
10 GΩ to 100 GΩ
> 100 GΩ
unspecified 
5 %
20 % 
unspecified
1000 V  < 200 kΩ
200 kΩ to 20 GΩ
20 GΩ to 200 GΩ
> 200 GΩ
unspecified
5 %
20 %
unspecified
2500 V  < 200 kΩ
200 kΩ to 50 GΩ
50 GΩ to 500 GΩ
> 500 GΩ
unspecified
5 %
20 %
unspecified
5000 V  < 200 kΩ
200 kΩ to 100 GΩ
100 GΩ to 1 TΩ
> 1 TΩ
unspecified
5 %
20 %
unspecified
10000 V
(1555 only)
 < 200 kΩ
200 kΩ to 200 GΩ
10 GΩ to 2 TΩ
> 2 TΩ
unspecified
5 %
20 %
unspecified
Bar graph range 0 to 1 TΩ 
Insulation test voltage accuracy -0 %, +10 % at 1 mA load current
Induced ac mains current rejection 2 mA maximum

Charging rate for capacitive load

5 seconds per μF 

Discharge rate for capacitive load

1.5 s/μF

Leakage current measurement

Range: 1 nA to 2 mA

Accuracy: ± (5 % + 2 nA)

Capacitance measurement

Range: 0.01 uF to 15.00 μF

Accuracy: ± (15 % rdg + 0.03 μF)

Timer

Range: 0 to 99 minutes

Resolution Accuracy: 
Setting: 1 minute 
Indication: 1 second

Live circuit warning

Warning Range: 
30 V to 660 V ac/dc, 
50/60 Hz

Voltage Accuracy: 
± (15 % + 2 V)

General specifications

Display 75 mm x 105 mm
Power 12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger Input (AC) Charger Input (AC) 85 V to 250 V ac 50/60 HZ 20 VA
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.
Dimensions 170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in)
Weight 3.6 kg (7.94 lb)
Temperature (operating) -20 ºC to 50 ºC (-4 ºF to 122 ºF)
Temperature (storage) -20 ºC to 65 ºC (-4 ºF to 149 ºF)
Humidity 80 % to 31 ºC decreasing linearly to 50 % at 50 ºC
Altitude 2000 m
Enclosure sealing IP40
Input overload protection 1000 V ac
Electromagnetic compatibility EN 61326
Safety compliance CAT III 1000 V, CAT IV 600 V